Related Experiment Video
Updated: Nov 15, 2025

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Sacral Insufficiency Fracture on 68Ga-DOTATATE PET/CT
Nuh Filizoglu1, Onur Bugdayci2, Salih Ozguven1
1From the Departments of Nuclear Medicine.
Gallium-68 DOTATATE PET/CT is useful for neuroendocrine tumors but can yield false positives. Sacral insufficiency fractures may mimic metastatic disease on PET/CT scans.
Area of Science:
- Nuclear medicine
- Oncology
- Radiology
Background:
- 68Ga-DOTATATE PET/CT is a key imaging modality for neuroendocrine tumors (NETs), including detecting skeletal metastases.
- Inflammatory conditions can present as false-positive findings on 68Ga-DOTATATE PET/CT scans.
- Sacral insufficiency fractures are a potential cause of false-positive uptake in the sacrum.
Observation:
- A 47-year-old male with pancreatic neuroendocrine tumor underwent 68Ga-DOTATATE PET/CT.
- The scan revealed abnormal 68Ga-DOTATATE uptake in the right sacral region.
- Subsequent MRI confirmed the presence of a sacral insufficiency fracture.
Findings:
- 68Ga-DOTATATE uptake in the sacrum on PET/CT can be indicative of a sacral insufficiency fracture.
- This finding highlights the potential for false-positive results in inflammatory conditions.
- Differentiating fracture uptake from true tumor metastasis is crucial for accurate diagnosis.
Implications:
- Awareness of false positives is essential when interpreting 68Ga-DOTATATE PET/CT scans in the sacral region.
- Integrating MRI findings is critical for accurate diagnosis and avoiding misinterpretation of inflammatory pathologies as metastatic disease.
- This case underscores the importance of correlating imaging findings with clinical context and other diagnostic modalities.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
09:5718F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...