Related Experiment Video
Updated: Nov 13, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Changes in lower limb alignment and their effect on the functional outcome after treatment of varus degenerative OA
Hrishikesh Pande1, Kamparsh Thakur2, Rajiv Dubey2
1Command Hospital, Lucknow, India.
Objective:
High tibial osteotomy (HTO) is an established procedure to treat medial compartmental osteoarthritis (OA) knee associated with varus deformity. It is well documented that precise correction of deformity and maintenance of correction achieved is important to ensure long term good results. This study was undertaken to record changes in radiological parameters and its effect on the functional outcomes in first two years following HTO done for varus degenerative OA kneeby hemicallotasis technique using HTO fixator.
Methods:
31 patients meeting our inclusion-exclusion criteria who underwent HTO by hemicallotasis method using self-adjusting unilateral HTO fixator were included in the study. Their femoro tibial angle (FTA), mechanical axis %, Insall- Salvati ratio, proximal tibial antero-posterior slope and knee injury and osteoarthritis outcome Score (KOOS) were recorded preoperatively, postoperatively at the time of removal of fixator, at 1 year and at 2 years.
Results:
The FTA and mechanical axis significantly improved from a mean of 183.12⁰ and -3.26% respectively preoperatively to 173.38⁰ and 61.81% at the time of removal of fixator but subsequently showed significant deterioration to 176.06⁰ and 57.96% at 1 year and further insignificant deterioration to 176.16⁰ and 57.74 at 2 years. The KOOS improved from mean 56.61 preoperatively to 70.48 at the time of fixator removal and further improved significantly to 85.68 at 1 year but significantly deteriorated to 84.54 at 2 years. The Insall-Salvati ratio, tibial slope showed no significant change throughout the study. Conclusion: Though desired alignment can be achieved by using the fixator, we found a significant deterioration in achieved radiological parameters after removal of fixator adversely affecting the functional outcome which is a matter of concern.
More Related Videos
09:01Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022