Related Experiment Video
Updated: Nov 12, 2025

Characterization of Sickling During Controlled Automated Deoxygenation with Oxygen Gradient Ektacytometry
Published on: November 5, 2019
Body temperature fatigue behaviour of reciprocating and rotary glide path instruments in sodium hypochlorite
Dario Perez-Villalba1, José C Macorra1, Juan J Perez-Higueras1
1Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, Madrid, Spain.
Abstract:
The aim of the study was to compare cyclic fatigue (CF) resistance of reciprocating and rotary glide path instruments in the presence of irrigation solutions at body temperature. CF resistance of 100 instruments (50 ProGlider and 50 WaveOne Gold Glider) was tested in sodium hypochlorite solutions alone (NaOCl) or in combination with etidronate (NaOCl/HEBP). The CF platform with a simulated canal (curvature = 60°/radius = 3 mm) was submerged in a temperature-controlled bath with the solutions kept at 37 ± 1°C controlled by a precision mercury glass thermometer. Instruments were actioned following manufacturer guidelines, and time to failure was recorded and compared among groups with Weibull analysis. Reciprocating glide path preparation instruments were more resistant to CF than rotary instruments in both irrigation solutions. The irrigation solution did not affect the mean life of ProGlider, but reciprocating instruments lasted significantly longer used in presence of NaOCl compared to NaOCl/HEBP.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Flame Photometry: Lab
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...