A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Development and validation of a gas chromatography method coupled with flame ionization detector for quantitative
Aleksandra Pawelec1, Bartosz Wielgomas1
1Department of Toxicology, Faculty of Pharmacy, Medical University of Gdańsk, Gdańsk, Poland.
Abstract:
Aromas can give smell and/or flavor to a variety of products in the cosmetic and food industry. They are also used as e-cigarette additives. Some of those substances are recognized as fragrance allergens and can cause allergic reactions so there is a need to control their use. Gas chromatography is the method of choice for analyzing fragrance allergens because of their low boiling points. This study aimed to develop and validate a robust and simple method for the analysis of fragrance allergens in aromas for e-cigarettes. A method using gas chromatography coupled with a flame ionization detector was developed for 25 fragrance allergens. Optimized parameters were sample diluent, internal standard, and carrier gas. The output method was the one previously developed and optimized. The linearity of the method was >0.994 over the range of 0.5-40 μg/mL. Accuracy and precision were within the acceptance range. Limits of detection and quantification were determined, and calibration curves were plotted. The method was applied to three real samples of aromas. Thirteen fragrance allergens were detected. Concentrations varied in the range of dozens to thousands of μg/mL showed that concentrations of fragrances in aromas for e-cigarettes can be high and varies among products.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
08:39Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Atomic Absorption Spectroscopy: Atomization Methods