Related Experiment Video
Updated: Nov 11, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Fibrotic Lung Disease at CT Predicts Adverse Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement
Cheng Ting Lin1, Matthew J Czarny1, Amira Hussien1
1Department of Radiology (C.T.L., A.H., E.K.F., S.L.Z.), Department of Medicine, Cardiology Division (M.J.C., R.K.H., J.R.R.), and Department of Medicine, Pulmonary and Critical Care Division (B.T.G.), Johns Hopkins University School of Medicine, 601 N Caroline St, JHOC 3171B, Baltimore, MD 21287.
Purpose:
To evaluate the relationship between CT findings of diffuse lung disease and post-transcatheter aortic valve replacement (TAVR) outcomes.
Materials And Methods:
Retrospective review of pre-TAVR CT scans obtained during 2012-2017 was conducted. Emphysema, reticulation, and honeycombing were separately scored using a five-point scale and applied to 10 images per examination. The fibrosis score was the sum of reticulation and honeycombing scores. Lung diseases were also assessed as dichotomous variables (zero vs nonzero scores). The two outcomes evaluated were death and the composite of death and readmission.
Results:
The study included 373 patients with median age of 84 years (age range, 51-98 years; interquartile range, 79-88 years) and median follow-up of 333 days. Fibrosis and emphysema were present in 66 (17.7%) and 95 (25.5%) patients, respectively. Fibrosis as a dichotomous variable was independently associated with the composite of death and readmission (hazard ratio [HR], 1.54; P = .030). In those without known chronic lung disease (CLD) (HR, 3.09; P = .024) and those without airway obstruction, defined by a ratio of forced expiratory volume in 1 second to the forced vital capacity greater than or equal to 70% (HR, 1.67, P = .039), CT evidence of fibrosis was a powerful predictor of adverse events. Neither emphysema score nor emphysema as a dichotomous variable was an independent predictor of outcome.
Conclusion:
The presence of fibrosis on baseline CT scans was an independent predictor of adverse events after TAVR. In particular, fibrosis had improved predictive value in both patients without known CLD and patients without airway obstruction.Supplemental material is available for this article.© RSNA, 2020.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT