Related Experiment Video
Updated: Nov 11, 2025

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
Published on: July 25, 2025
CFD analysis of a H2O2/UVC water treatment process in the annular FluHelik reactor
Sayonara Vanessa de Medeiros Lima1, Natan Padoin2, Cíntia Soares3
1Laboratory of Materials and Scientific Computing (LabMAC), Department of Chemical and Food Engineering, Federal University of Santa Catarina, Campus Universitário Reitor João David Ferreira de Lima, Florianópolis, SC, 88040-900, Brazil.
Abstract:
This study deals with the photochemical degradation of the model compound tetracycline, an aqueous pollutant derived from the degradation of the bactericide oxytetracycline (OTC), in the innovative photoreactor FluHelik, designed to promote pollutant abatement in liquid phase through H2O2/UVC and UVC processes. Computational fluid dynamics (CFD) simulations were performed to predict the behavior of the photoreactor in the laboratory scale. The simulations revealed a well-defined helicoidal flow pattern around the UVC lamp in the photoreactor, and the effect of different operational conditions (e.g., flow rate and light intensity) on the reactor's performance was evaluated, allowing to optimize the equipment.