An 18.3 MJ charging and discharging pulsed power supply system for the Space Plasma Environment Research Facility

Peng E1, Jian Guan1, Wenbin Ling1

  • 1Laboratory for Space Environment and Physical Sciences, Harbin Institute of Technology, Harbin 150001, Heilongjiang, China.

Related Concept Videos

Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
392
Design Example: Capacitance Multiplier Circuit01:20

Design Example: Capacitance Multiplier Circuit

In integrated circuit technology, a capacitance multiplier is often utilized to produce a larger capacitance value when a small physical capacitance falls short. This is achieved by a circuit that multiplies capacitance values by a factor of up to 1000, such that a 10-pF capacitor can replicate the performance of a 100-nF capacitor.
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
1.1K
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
439
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
737
Continuous Charge Distributions01:17

Continuous Charge Distributions

Imagine a bucket of water. It contains many molecules, of the order of 1026 molecules. Thus, although it contains discrete elements (molecules) at the microscopic level, macroscopically, it can be considered continuous. Small volume elements of water, infinitesimal compared to the bulk of the bucket's volume, still contain many molecules. Under this framework, quantized matter is approximated as continuous for practical purposes.
The electric charge can also be subjected to an analogical...
7.6K
Full wave rectifier01:22

Full wave rectifier

A full-wave rectifier is a device that converts alternating current (AC) to direct current (DC) and is more efficient than its half-wave counterpart. It typically includes a center-tapped transformer, two diodes, and a load resistor. The secondary winding of the transformer is divided to provide two equal voltages of opposite polarities, which is the pivotal element of full-wave rectification.
2.2K