A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
A Noninvasive Method for Monitoring Intracranial Pressure During Postural Changes
Michele L Pierro1, Nikole M Shooshan2, Saukhyda Deshmukh2
1Vivonics, Inc., Bedford, MA, USA. mpierro@vivonics.com.
Abstract:
Intracranial hypertension (IH) is an important cause of secondary brain injury, and its association with poor outcomes has been extensively demonstrated. Pathological intracranial hypertension is defined as a persistent rise in intracranial pressure (ICP) to above 20-25 mmHg, with symptoms such as headaches, loss of consciousness, seizures, and focal deficits, as well as ischemic damage. Therefore, monitoring of ICP is invaluable in the management of these symptoms. However, invasive measurements of ventricular pressure (requiring a surgical procedure) are considered the gold standard, thus limiting the practicality of ICP measurements. Vivonics, Inc., is developing a noninvasive optical device to assess ICP for use by emergency medical personnel, called IPASS: Intracranial Pressure Assessment and Screening System. IPASS uses four near-infrared sensors to measure hemodynamic oscillations at four different locations. Three sensors are used as reference signals and one sensor is used to detect cerebral blood volume oscillations. Pulse arrival delays between the measured cerebral blood volume oscillations and the blood volume oscillations measured at the three reference locations are calculated and correlated with estimated ICP changes, herein modulated by specific positional changes (in a head-down maneuver).
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement