Related Experiment Video
Updated: Nov 9, 2025

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
A Practical Approach to Filtering Facepiece Respirator Decontamination and Reuse: Ultraviolet Germicidal Irradiation
Mark P Ridder1, Katie D Paladino2, John J Lowe3
1Division of Infectious Disease, University of Nebraska Medical Center, 985400 Nebraska Medical Center, Omaha, NE 68198-5400 USA.
Purpose Of Review:
Prior outbreaks of respiratory viruses have demonstrated the need for adequate personal protective equipment (PPE) for healthcare workers, particularly filtering facepiece respirators (FFR). Due to shortfalls of PPE during the SARS CoV-2 pandemic, the need for FFR decontamination and reuse (FFR-DR) strategies is paramount. This paper aims to discuss primary decontamination strategies, with an in-depth analysis of ultraviolet germicidal irradiation (UVGI), arriving at the decontamination strategy utilized at the Nebraska Medical Center (NMC).
Methods:
Review of the primary literature in regard to FFR-DR as well as a synopsis of the current protocol for FFR-DR at NMC.
Recent Findings:
UVGI demonstrates effective decontamination of multiple pathogens-including several human respiratory viruses-while maintaining mask integrity and filtering capacity. UVGI was associated with degradation of strap integrity at higher doses than that utilized for decontamination or with reuse beyond 20 times.
Summary:
UVGI effectively decontaminates N95 FFRs without significant reduction to fit or strap integrity and can be employed as a strategy for FFR-DR in times of emergency.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
PPE Use in Healthcare Settings II: Doffing
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
PPE Use in Healthcare Settings I: Donning
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...