Validation of a new wearable device for type 3 sleep test without flowmeter
Mauro Contini1, Antonio Sarmento2, Paola Gugliandolo1
1Centro Cardiologico Monzino, IRCCS, Milano, Italy.
Plos One
|April 16, 2021
Summary
This study shows that the X10X and X10Y wearable systems can accurately detect and classify sleep apnea events, offering a comfortable alternative to traditional sleep test instrumentation.
Area of Science:
- Sleep Medicine
- Respiratory Physiology
- Medical Device Technology
Background:
- Traditional sleep monitoring devices often cause patient discomfort due to flowmeter use.
- Accurate detection of sleep apnea events is crucial for effective treatment.
Purpose of the Study:
- To evaluate the efficacy of the innovative wearable X10X and X10Y systems.
- To determine if these devices can detect and classify sleep apnea severity without a flowmeter.
Main Methods:
- Simultaneous recording of X10X/X10Y and a certified Type 3 system (SOMNOtouch) in 40 patients.
- Evaluation of respiratory signal quality, apnea/hypopnea duration, and classification accuracy.
Main Results:
- High agreement (grades 4-5 in 383/580 cases) and correlation (r2=0.921) between X10X/X10Y and SOMNOtouch.
- Accurate classification rates for obstructive (72.3%), central (81%), hypopneas (61.3%), and mixed apneas (64.6%).
Conclusions:
- X10X and X10Y devices provide accurate sleep respiratory disorder grading without nasal cannula flow measurement.
- These wearable systems are suitable for Type 3 sleep testing and screening.
Related Concept Videos
Equipments Used To Measure Blood Pressure
2.7K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.7K
Pulse Oximetry
1.0K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.0K
Holter Monitor: 24-Hour Monitoring
725
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
725