An 18.8-33.9 GHz, 2.26 mW Current-Reuse Injection-Locked Frequency Divider for Radar Sensor Applications

Kwang-Il Oh1, Goo-Han Ko1, Jeong-Geun Kim2

  • 1Microwave Embedded Circuit & System (MECAS) Lab., School of Electrical Engineering, Chung-Ang University, 84 Heukseok, Dongjack, Seoul 06974, Korea.

Related Concept Videos

Voltage Dividers01:14

Voltage Dividers

In electrical circuits, resistors can be connected in series, sequentially linked one after the other. In a series configuration, the same current flows through each resistor. Ohm's law is a fundamental principle to understand the behavior of resistors in series. It expresses the voltage across these resistors in terms of the current and resistance.
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
985
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.2K
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
1.4K
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.3K
Cut-off Frequency of BJT01:17

Cut-off Frequency of BJT

Cut-off frequencies in Bipolar Junction Transistors (BJTs) mark the transition between the signal's pass band and stop band, influencing their performance in amplifying or attenuating frequencies. These frequencies are crucial for designing BJTs to meet specific operational requirements in electronic circuits.
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
1.0K
IR Frequency Region: X–H Stretching01:24

IR Frequency Region: X–H Stretching

In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of  2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.2K