Related Experiment Video
Updated: Nov 6, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
A substantial increase of analytical throughput in capillary electrophoresis throughput by separation-interrupted
Hongliang Li1, Chao Guo1, Qianchun Zhang2
1Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China. chenyi@iccas.ac.cn and University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
How to further improve the throughput of capillary electrophoresis (CE) is a fascinating question. Herein an idea to substantially increase the throughput of CE has been proposed together with theory and experimental demonstration. The key is to introduce samples for CE, one after another, by a short suspension of voltage application, which was hence termed separation-interrupted sequential injections (Sisi). The idea was demonstrated to be feasible on a laboratory-built CE instrument coupled with tandem C4D (contactless capacitively-coupled conductivity) detectors. At least 50 injections of a testing sample (mixture of NH4+, K+, Ca2+, Na+ and Mg2+) were successfully separated in only a single run. The separation took 145 min in total, equivalent to 2.9 min per analysis which is only 21% of that of normal CE. Quantification of the separated ions was performed, with a limit of detection of 1.1-2.6 μM, a limit of quantification of 3.2-8.9 μM, and a linear range up to 1000 μM (R2 > 0.99). The recovery was between 88% and 112% measured by spiking standards into samples at low, middle and high levels. The real applicability of Sisi-CE was evaluated by direct injection and analysis of 45 mineral water samples also in a single run. Its clinical application potential was demonstrated by high throughput assay of the calcium and zinc gluconate oral solution formula, and the blood potassium of hyperkalemia and hypokalemia from patients with renal failure disease. This method can be extended to other applications such as omics studies through the use of more suitable detectors. The theory proposed may also be applicable to other high throughput methods.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...

