Phase of white light and its compatibility to the optical path
Abstract:
The phase of monochromatic light directly relates to the optical path difference (OPD), but finding this connection for spectrally broadband light is challenging. Due to a missing concept of the compatibility between the phase of randomly fluctuating fields and the OPD, demanding scanning is the only proven way for a highly accurate OPD measurement in white light. Here, we use the self-coherence function (SCF) of the spatially incoherent light to reveal the connection between the white-light phase and the OPD. Our method uses an associated field assigned to the SCF to mimic the intensity oscillation of a correlation pattern. The associated field allows restoring a cumulative OPD integrated into the SCF across all spectral constituents. The method is essential for quantitative phase microscopy, in which the SCF is available even in white light, but its processing beyond the quasi-monochromatic approach is still lacking. Improper assessment of the white-light phase may result in a loss of measurement accuracy, as we demonstrate theoretically and experimentally. Deploying our method in coherence-controlled holographic microscopy, we measured the cumulative OPD in the broadband light with a strongly asymmetric spectrum (bandwidth of 150 nm), achieving accuracy better than 5 nm in the measuring depth range of 2 µm.
Related Concept Videos
Interference and Diffraction
The Wave Nature of Light
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Photoreceptors and Visual Pathways
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...