Related Experiment Video
Updated: Nov 5, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Multi-frequency differential absorption lidar incorporating a comb-referenced scanning laser for gas spectrum
Abstract:
A multi-frequency differential absorption lidar incorporating a tunable laser and an optical frequency comb is demonstrated for precise spectrum analysis of atmospheric gas. The single frequency tunable laser is stabilized by locking to the optical frequency comb, with a standard deviation of 0.5 MHz. To achieve a high signal-to-noise ratio, a multi-mode superconducting nanowire single-photon detector with an active-area diameter of 50 µm, a quantum efficiency of 31.5%, and dark noise of 100 counts per second is implemented, which enables to avoid the need for high energy lasers. In the experiment, the range-resolved spectrum of atmospheric mixture gases (CO2 and HDO) in a region of 1572.2 - 1572.45 nm is obtained. Results show different partially overlapped absorption of two gases in different seasons, with a stronger influence of HDO on CO2 in summer than in winter. The interactions are taken into account by separating the mixture absorption spectrum (one CO2 line and two HDO lines) with triple-peak Voigt fitting. The retrieved concentrations over 6 km with a range resolution of 120 m and a time resolution of 10 min are compared with in-situ sensors. The uncertainties of the retrieved concentrations are as low as 6.5 µmol/mol (ppm) and 1×10-3 g/kg for CO2 and HDO, respectively.
More Related Videos
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
09:22Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry
Published on: September 3, 2010
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...