Discharge Behaviour and Modelling of a 1.5T REBCO Magnet With Quench Tolerant Coils Impregnated with Conductive Epoxy
Konstantinos Bouloukakis1, Mark Hunter2, Nicholas Long1
1Robinson Research Institute, Victoria University of Wellington, PO Box 33436, Lower Hutt 5046, New Zealand.
Abstract:
We have designed and built a small, conduction cooled, 1.5 T high-temperature superconductor (HTS) magnet. The magnet coils have been wet-wound with a novel conductive epoxy resin system to achieve a derivative of the no-insulation coil winding method. The epoxy is filled with copper powder to reliably set the turn-to-turn contact resistivity and diamond powder to accurately space the coil turns apart, as well as match the filled epoxy thermal contraction rate to that of the HTS. The magnet is designed to act as a test bed to measure sudden discharge rates and hence validate models of coil behaviour using the filled epoxy system we have developed. A lumped-element electrical model was used to predict the coil contact resistivity needed to bring the magnetic field of the 1.5 T magnet down to a near-zero level within 0.5 s. The conductive epoxy blend was tuned to give a contact resistivity of 1 × 10-6 Ω m2, based on previous measurements of coil contact resistivity at 77 K. Once the magnet was wound and tested at 40 K, we found the magnet's sudden discharge time constant was 500 ms rather than 69 ms as was predicted from the 77 K measurements. The discrepancy was traced to the temperature dependence of the contact resistivity. With further testing of the individual coils this was accounted for and the model adjusted. The predicted discharge time was 2 s, in good agreement with the measured sudden discharge time of the magnet.
More Related Videos
11:27Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
Published on: April 4, 2013
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Related Concept Videos
Charging Conductors By Induction
Generally, conductors like metals do not allow any excess charge to be present on them. Any excess charge added to metals easily flows away, for example, when a metal is placed on the Earth. This process is called earthing.
However, conductors can be charged by a process called induction. For example, consider charging a...
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Force On Current-Carrying Wires: Example
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Motional Emf