Measuring Cardiac Output in a Swine Model.
Neerav Patel1, Hossam Abdou2, Joseph Edwards2
1R Adams Cowley Shock Trauma Center, University of Maryland Medical System; nppatel@som.umaryland.edu.
Journal of Visualized Experiments : Jove
|May 31, 2021
Summary
Three methods for measuring swine cardiac output—PV-loop catheters, contrast ventriculography, and thermodilution—showed high accuracy and correlation. These techniques are reliable for assessing stroke volume and cardiac output in swine research.
Area of Science:
- Cardiovascular Physiology
- Medical Research Methodologies
- Animal Models in Research
Background:
- Swine are valuable models for human cardiac research due to physiological similarities.
- Accurate measurement of cardiac parameters like stroke volume and cardiac output is crucial in swine studies.
- Established methods for cardiac assessment include contrast ventriculography, thermodilution, and pressure-volume loop (PV-loop) catheters.
Purpose of the Study:
- To compare the accuracy and correlation of three distinct methods for measuring cardiac output and stroke volume in swine.
- To evaluate the reliability of PV-loop catheters, contrast ventriculography, and thermodilution in a live swine model.
- To determine the most suitable method based on available resources and research needs.
Main Methods:
- Five Yorkshire swine underwent anesthesia and instrumentation for central venous and arterial access.
- Cardiac output was measured using thermodilution (cold saline bolus and temperature probe).
- Stroke volume and cardiac output were assessed via contrast ventriculography (left ventricular catheter and iodinated contrast) and PV-loop catheter (continuous pressure-volume data).
Main Results:
- All three methods demonstrated strong correlations with each other.
- PV-loop catheter and thermodilution showed the highest correlation (r=0.99, 3% error).
- PV-loop catheter and contrast ventriculography (r=0.95, 6% error); thermodilution and contrast ventriculography (r=0.95, 2% error) also showed good agreement.
Conclusions:
- PV-loop catheters, contrast ventriculography, and thermodilution are reliable and accurate for measuring cardiac parameters in swine.
- Each method offers advantages, allowing researchers to choose based on specific requirements and available resources.
- These validated techniques support robust cardiovascular research using swine models.