Background:
Pseudohyponatremia describes an artifactual decrease in plasma sodium result in samples with high proteins and/or lipids when measured by an indirect ion-selective electrode (ISE) method. We suspected that Intralipid®-based lipemia cutoffs are inappropriate for detecting interfering lipids in human samples and a major contributing factor to the existence of pseudohyponatremia.
Methods:
We evaluated 2 approaches to derive a lipemia cutoff for sodium, one in which patient plasma samples were pooled and spiked to simulate hyperlipidemia using Intralipid® (commonly used approach by in-vitro diagnostics manufacturers), and another in which endogenous hyperlipidemic samples (n = 31) were measured by methods not affected by hyperlipidemia (i.e., direct ISE and post-ultracentrifugation indirect ISE). Triglycerides, lipemic index (L-index) and indirect ISE sodium concentrations of samples were measured on Roche Cobas® 8000 and direct ISE on Radiometer® ABL835 Flex analyzers. Endogenous hyperlipidemic samples were also ultracentrifuged on Beckman Coulter® Airfuge to clear excess lipids and re-analyzed for sodium by indirect ISE.
Results:
We discovered that Intralipid® is not an accurate emulation of the lipemic interference seen in pseudohyponatremia because it showed no effect up to the maximum level of lipemia tested (L-index = 2000). By contrast, endogenous hyperlipidemic samples demonstrated significant deviations in sodium concentration (≥4 mmol/l) when L-index approached or exceeded 700, and a strong positive correlation between L-index and the difference between the indirect and direct methods (i.e., extent of pseudohyponatremia).
Conclusions:
Clinical laboratories should lower their tolerance for lipemia from the currently recommended L-index cutoff of 2000 on Roche Cobas 8000®. We recommend reflexing to direct ISE when L-index exceeds 700. Manufacturers and laboratories with other indirect ISE methods should evaluate the effect of lipid interference on their method using hyperlipidemic human samples not Intralipid®.
Related Concept Videos
Nephrotic Syndrome III : Nursing Management
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...
Nephrotic Syndrome II : Assessment and Medical Management
Antihypertensive Drugs: Potassium-Sparing Diuretics
Acute Kidney Injury VI: Nursing Management
Regulation of Sodium and Potassium
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...