Related Experiment Video
Updated: Nov 3, 2025

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet VUV Synchrotron Radiation
Published on: October 30, 2012
Dissociation of Biomolecules by an Intense Low-Energy Electron Beam in a High Sensitivity Time-of-Flight Mass
Takashi Baba1, Pavel Ryumin1, Eva Duchoslav1
1Sciex, 71 Four Valley Drive Concord, Ontario L4K 4V8, Canada.
Abstract:
We report the progress on an electron-activated dissociation (EAD) device coupled to a quadrupole TOF mass spectrometer (QqTOF MS) developed in our group. This device features a new electron beam optics design allowing up to 100 times stronger electron currents in the reaction cell. The electron beam current reached the space-charge limit of 0.5 μA at near-zero electron kinetic energies. These advances enable fast and efficient dissociation of various analytes ranging from singly charged small molecules to multiply protonated proteins. Tunable electron energy provides access to different fragmentation regimes: ECD, hot ECD, and electron-impact excitation of ions from organics (EIEIO). The efficiency of the device was tested on a wide range of precursor charge states. The EAD device was installed in a QqTOF MS employing a novel trap-and-release strategy facilitating spatial mass focusing of ions at the center of the TOF accelerator. This technique increased the sensitivity 6-10 times and allows for the first time comprehensive structural lipidomics on an LC time scale. The system was evaluated for other compound classes such as intact proteins and glycopeptides. Application of hot ECD for the analysis of glycopeptides resulted in rich fragmentation with predominantly peptide backbone fragments; however, glycan fragments attributed to the ECD process were also observed. A standard small protein ubiquitin (8.6 kDa) was sequenced with 90% cleavage coverage at spectrum accumulation times of 100 ms and 98% at 800 ms. Comparable cleavage coverage for a medium-size protein (carbonic anhydrase: 29 kDa) could be achieved, albeit with longer accumulation times.
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Overview
Mass Spectrometers
Chemical Ionization (CI) Mass Spectrometry
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...

