Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Initial and volume recombination losses in gamma versatile ionization chamber VGIC for gamma ray dosimetry
Mohamed Fares1, Adnane Messai1, Mohammed Messaoudi2
1Laboratory of Nuclear Detectors, Department Detection and Measurement, Nuclear Research Centre of Birine, P.o.Box 180, Ain Oussera, 17200, Djelfa, Algeria.
Abstract:
A versatile gamma ionization chamber (VGIC) has been designed, developed and characterized, in order to study experimentally its characteristics according to the geometry of the electrodes, the volume and pressure of the filler gas for the design of a gamma sealed chamber. The tests were conducted under the IEC (International Electro-technical Commission). The results obtained in various nuclear tests of the characterization and calibration of the ionization chamber gamma VGIC developed at our laboratory were presented in this paper. Three irradiators were operated, irradiator intensive gamma (60Co: 1.25 MeV), medium intensive gamma (137Cs: 0.662 MeV) and low-intensity gamma (60Co). Saturation curves and linearity were identified and the operating range and the sensitivity of the chamber have been deducted. The current, voltage (I,V) characteristics of the chamber filled, with argon gas at 0.4 M pa pressure, for gamma ray irradiator sources were studied, the chamber was irradiated with gamma rays using different gamma sources. The plateau region is reached above 200 V and the detector operating voltage is found to be 600V. It is observed that in the plateau region the slope is constant with an increase in the exposure rate. The (1/I, 1/V) and (I, l/V2) characteristic curves reveal the presence of the initial and volume recombination losses. The volume recombination losses are found to be smaller than the initial recombination losses.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Absorption of Radiation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...