Related Experiment Video
Updated: Nov 2, 2025

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Impact of GBBS algorithm on post-mastectomy scar boost irradiation of breast using catheter flap
Mourougan Sinnatamby1, Vijayaprabhu Neelakandan1, Gunaseelan Karunanidhi1
1Department of Radiation Oncology, Regional Cancer Centre, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Purpose:
Post-mastectomy radiation therapy significantly reduces locoregional recurrence rates, which can be achieved with external beam radiotherapy delivered to chest wall, followed by scar irradiation either by electron or high-dose-rate (HDR) mould brachytherapy. The present study evaluates dosimetric advantage of Acuros® BV, a TG-186 MBDCA, over TG-43 formalism using 192Ir source for HDR brachytherapy in chest wall scar boost using catheter flap.
Material And Methods:
A total of 25 patients, free of cardiac and pulmonary co-morbidities, who met the inclusion criteria were involved in the study. Catheter flap made of silicon with 20 channels was used to deliver a total dose of 7.5 Gy/3 fx by HDR surface mould brachytherapy to delineated scar volume. Plan was optimized with iterative method to obtain desired results with TG-43 formalism, followed by Acuros® BV (GBBS algorithm) without altering dwell positions or time. The two algorithm plans were analyzed qualitatively and quantitatively with dose-volume histograms.
Results:
The mean D98% CTV-HDR_evl coverage decreased by 1.16% compared to TG-43, and near-maximum dose decreased by 8.18% (p = 0.000), mean Dmax dose to CTV-HDR_evl, and mean Dmean dose was lesser by 6.25% (p = 0.000) and 10.82% (p = 0.000), respectively, compared to TG-43. Heart D2% showed significant results, whereas Dmedian (cGy) revealed very significant difference. A 5 mm thick skin contour showed statistically significant results (p = 0.000) for V150% and V200%.
Conclusions:
The presented data showed how Acuros® BV, algorithm-based calculation in scar boost irradiation of breast, accounting for a mass density of the medium and scatter condition, considered actual dose prediction in a medium.