Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

843
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
843
Multicompartment Models: Overview01:14

Multicompartment Models: Overview

322
Multicompartment models are mathematical constructs that depict how drugs are distributed and eliminated within the body. They segment the body into several compartments, symbolizing various physiological or anatomical areas connected through drug transfer processes such as absorption, metabolism, distribution, and elimination.
These models offer a more comprehensive representation of drug behavior in the body than one-compartment models. They accommodate the complexity of drug distribution,...
322
Clearance Models: Noncompartmental Models01:17

Clearance Models: Noncompartmental Models

123
Clearance is a pharmacokinetic parameter traditionally defined by compartment models, signifying the rate at which a drug is expelled from the body. However, a noncompartmental model offers an alternative method for assessing clearance, primarily employing empirical data obtained after administering a single drug dose.
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...
123
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

430
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
430
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

145
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
145
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis00:59

Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis

158
Noncompartmental analyses offer an alternative method for describing drug pharmacokinetics without relying on a specific compartmental model. In this approach, the drug's pharmacokinetics are assumed to be linear, with the terminal phase log-linear. This assumption allows for simplified analysis and interpretation of the drug's behavior in the body.
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
158

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ruthenium-catalyzed oxidative cleavage of olefins to aldehydes.

The Journal of organic chemistry·2001
Same author

Pharmacokinetics of testosterone after percutaneous gel or buccal administration.

Fertility and sterility·2001
Same author

The leukocyte common antigen-related protein tyrosine phosphatase receptor regulates regenerative neurite outgrowth in vivo.

The Journal of neuroscience : the official journal of the Society for Neuroscience·2001
Same author

Calpain activity in the rat brain after transient forebrain ischemia.

Experimental neurology·2001
Same author

Sharpening low-energy, standard-model tests via correlation coefficients in neutron beta decay.

Physical review letters·2001
Same author

Creation of chimeric mutant axolotls: a model to study early embryonic heart development in Mexican axolotls.

Anatomy and embryology·2001
Same journal

From Geometry to Intensity: A Coarse-to-Fine Pipeline for Unsupervised 3D Ultrasound Stitching.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

AVA: Automated Viewability Analysis for Ureteroscopic Intrarenal Surgery.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Kidney Endoscopy Video to Preoperative CT Alignment for Depth Estimation.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Deep learning‑based cell type prediction in lung tissue from brightfield histology using CODEX-derived labels.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Reconstructing physiological signals from fMRI across the adult lifespan.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Axially Swept Light-Sheet Microscopy using scattering and fluorescence contrast mechanisms.

Proceedings of SPIE--the International Society for Optical Engineering·2026
See all related articles

Related Experiment Video

Updated: Oct 31, 2025

Three-Dimensional Shape Modeling and Analysis of Brain Structures
05:33

Three-Dimensional Shape Modeling and Analysis of Brain Structures

Published on: November 14, 2019

7.3K

Polyenergetic Known-Component Reconstruction without Prior Shape Models.

C Zhang1, W Zbijewski1, X Zhang1

  • 1Department of Biomedical Engineering, Johns Hopkins University, Baltimore MD, USA 21205.

Proceedings of Spie--The International Society for Optical Engineering
|June 30, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces model-free known-component reconstruction (MF-Poly-KCR) for CT imaging. This technique significantly reduces metal artifacts and improves image quality without needing prior implant models, enabling broader clinical use.

More Related Videos

Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

11.1K
Cortical Source Analysis of High-Density EEG Recordings in Children
09:32

Cortical Source Analysis of High-Density EEG Recordings in Children

Published on: June 30, 2014

21.6K

Related Experiment Videos

Last Updated: Oct 31, 2025

Three-Dimensional Shape Modeling and Analysis of Brain Structures
05:33

Three-Dimensional Shape Modeling and Analysis of Brain Structures

Published on: November 14, 2019

7.3K
Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

11.1K
Cortical Source Analysis of High-Density EEG Recordings in Children
09:32

Cortical Source Analysis of High-Density EEG Recordings in Children

Published on: June 30, 2014

21.6K

Area of Science:

  • Medical Imaging
  • Computed Tomography (CT)
  • Image Reconstruction

Background:

  • Metal artifacts in CT scans, caused by surgical tools and implants, degrade image quality and hinder diagnosis.
  • Model-based CT reconstruction methods, including known-component reconstruction (KCR), can reduce these artifacts.
  • Existing KCR methods often require detailed prior knowledge of the metal component's physical model (e.g., CAD files).

Purpose of the Study:

  • To extend the polyenergetic formulation of known-component reconstruction (Poly-KCR) by removing the need for a priori physical models.
  • To develop and evaluate a model-free KCR (MF-Poly-KCR) approach for improved CT image quality in the presence of metal implants.
  • To enable wider application of KCR techniques in clinical settings where implant information may be limited.

Main Methods:

  • A single-threshold segmentation technique with morphological structuring elements was used to create a shape model of metal components from an initial filtered-backprojection (FBP) reconstruction.
  • This model-free shape information was input into the Poly-KCR algorithm, which does not require prior knowledge of beam quality or material composition.
  • Performance was evaluated through simulation studies, comparing MF-Poly-KCR to FBP and Poly-KCR with a priori models using physical CBCT data and patient scans.

Main Results:

  • MF-Poly-KCR significantly improved image quality compared to conventional FBP reconstruction.
  • The performance of MF-Poly-KCR closely approximated that of Poly-KCR using a priori shape models.
  • The method effectively reduced blooming and streak artifacts, allowing for better visualization of surrounding soft tissues.

Conclusions:

  • Known-component reconstruction is feasible without prior knowledge of the specific metal component.
  • The combination of MF-Poly-KCR and Poly-KCR minimizes the need for pre-existing information about implants and imaging systems.
  • These advancements facilitate broader clinical adoption of KCR for patient studies, especially when implant details are unavailable.