Related Experiment Video
Updated: Oct 30, 2025

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Multivariate optimization of dual-sorbent dynamic headspace extraction of volatiles in wine analysis
Olga Vyviurska1, Mária Hanobiková1, Adriano A Gomes2
1Slovak University of Technology in Bratislava, Faculty of Chemical and Food Technology, Institute of Analytical Chemistry, 81237 Bratislava, Slovak Republic.
Abstract:
The main critical point of newly developed miniaturized sample preparation techniques is a limited extraction capacity. Dynamic headspace extraction offers increased volume of sorbent which is commonly used in environmental analysis. Application of two sorbents (Carbopack B/Carbopack X and Tenax® TA) at different extraction temperatures allows enhancing a range of volatile organic compounds available for analysis. Such approach was applied in our research for quantification of volatile organic compounds in botrytized wines with gas chromatography. The central composite design was included to analysis simultaneous effects of incubation time, incubation temperature, purge volume and purge flow. In attempt to properly assess results, the data evaluation involved Pareto charts, surface response methodology and principal component analysis. Multivariate experimental design revealed statistical significance of purge volume and quadratic terms of incubation time and temperature, for response of volatiles. The quantification method with 0.2-2.0 µg/L LOD and 0.5-5.0 µg/L LOQ values, was developed under simultaneously optimized experimental conditions such as a 54 °C incubation temperature, a 20.18 min incubation time, a 344.3 mL purge volume and a 16.0 mL/min purge flow. The increased levels of linalool oxide, ethyl phenylacetate, γ-hexalactone and α-terpineol were observed in the samples, that correlated with botrytized wine technology.
More Related Videos
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Volatilization
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Elution Process
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...