A Noninvasive Miniaturized Transcutaneous Oxygen Monitor
Abstract:
Transcutaneous monitoring is a noninvasive method to continuously measure the partial pressures of oxygen and carbon dioxide that diffuse through the skin and correlate closely with changes in blood gases. However, the contemporary commercially available electrochemical-based technology requires a heating mechanism and a bulky, corded, and expensive sensing unit. This study aims to demonstrate a prototype noninvasive, miniaturized monitor that uses luminescence-based technology to measure the partial pressure of transcutaneous oxygen, a surrogate of the partial pressure of arterial oxygen. To be able to build a robust measurement system, we conducted experiments to understand the temperature and humidity dependence of oxygen-sensitive platinum-porphyrin films. We performed a detailed analysis of both intensity and lifetime measurement techniques. To verify the performance, we tested the prototype in a small ex-vivo experiment involving three healthy human volunteers. We measured variations in the partial pressure of transcutaneous oxygen values due to pressure-induced arterial and venous occlusions on the volunteers' fingertips. The system resolves changes in the partial pressure of oxygen from 0 to 418 mmHg in the lab bench-top testing, covering the medically relevant range of 50-150 mmHg. Under fixed humidity, temperature, and the partial pressure of oxygen conditions, the sensor shows a 2% drift over 60 hours. The prototype consumes 9 mW of power from a 2.2 V external DC power supply.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...