Frequency response mismatch calibration in 2-channel time-interleaved oscilloscopes
Zhixiang Pan1, Peng Ye1, Kuojun Yang1
1School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.
Abstract:
The time-interleaved (TI) structure has been widely implemented in high speed, wideband data acquisition systems to increase the system sampling rate. However, the frequency responses of each sub-sampling path are not identical. This is named frequency response mismatches (FRMs). In TI-based printed circuit board level systems, due to the impact of the parasitic parameters, the FRMs are more complicated than the mismatches in TI analog-to-digital converters (TIADCs), which degrade the system performance severely. Therefore, the FRM calibration in 2-channel TI acquisition systems with two features is researched. The first one is that the TI system has a larger mismatch range than in most previous research. The second one is that the channel frequency response uses the general model. The calibration structure is established by the analysis of the digital TI model, which implements the TI operation in the digital domain to reconstruct the mismatches in the time domain. Furthermore, the problem of designing an arbitrary frequency response filter is transformed to the question of designing a three-stage cascaded filter group, which gives a method to realize the arbitrary frequency response in a real system. An oscilloscope prototype is proposed to verify the calibration performance. The simulation and experiment show the following: (i) Even though it uses the general frequency response and the FRMs are significant, the proposed method is still effective. (ii) The mismatch range of magnitude and phase responses is highly suppressed, and the spurious-free dynamic range is improved by 16.26 dB after calibration of the prototype.
Related Concept Videos
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Frequency Response of Op Amp Circuits
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies,...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Sampling Theorem