Related Experiment Video
Updated: Oct 29, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Diagnostic Validation of a High-Sensitivity Cardiac Troponin I Assay
Nils A Sörensen1,2, Alina Goßling1, Johannes T Neumann1,2,3
1Department of Cardiology, University Heart and Vascular Center Hamburg, Hamburg, Germany.
Background:
Emergency departments worldwide are increasingly adopting rapid diagnosis of patients with suspected myocardial infarction (MI) based on high-sensitivity troponin. We set out to assess the diagnostic accuracy of a high-sensitivity cardiac troponin I (hs-cTnI) assay in a prospective study.
Methods:
In a cohort study including 1800 patients presenting with suspected acute MI, we developed and temporally validated a 0/1 h diagnostic algorithm using the Siemens Atellica IM hs-cTnI assay. The algorithm was established in the first 928 patients and validated in the following 872 patients.
Results:
The derived algorithm consisted of a baseline rule-out of non-ST-segment elevation MI using a cutoff <3 ng/L in patients with symptom onset ≥3 h or an admission troponin I level <6 ng/L with a Δ change of <3 ng/L from 0 h to 1 h. For rule-in, an admission troponin I level ≥120 ng/L or an increase within the first hour ≥12 ng/L was required. Application of the algorithm to the validation cohort showed a negative predictive value of 99.8% (95% CI, 98.7%-100.0%), sensitivity of 99.1% (95% CI, 95.1%-100.0%), and 48.3% of patients ruled out, whereas 15.1% were ruled in with a positive predictive value of 68.0% (95% CI, 59.1%-75.9%) and specificity of 94.4% (95% CI, 92.5%-96.0%). The diagnostic performance was comparable to guideline-recommended application of an established hs-cTnI assay in a rapid 0/1 h strategy.
Conclusions:
The Siemens hs-cTnI assay is well suited for application in rapid diagnostic stratification of patients with suspected MI.
Study Registration:
www.clinicaltrials.gov (NCT02355457).
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction
Myocarditis II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Receiver Operating Characteristic Plot