Related Experiment Video
Updated: Oct 28, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Radiation dose rate variations in different measurement scenarios after prostate 125I brachytherapy
Takashi Hanada1, Atsunori Yorozu2, Riki Kikumura2
1Department of Radiology, Keio University School of Medicine, Shinjuku-ku, Tokyo, Japan; Department of Radiology, National Hospital Organization Tokyo Medical Center, Meguro-ku, Tokyo, Japan.
Purpose:
This study aimed to directly compare different measurement scenarios using a supplemental radiation exposure measurement data set.
Materials And Methods:
Two sets of measurement scenarios comparing different body postures, such as standing and chair sitting positions, and different measurement directions, such as anterior and posterior directions, were assessed for radiation dose rate variations in this study at the Tokyo Medical Center, Japan. The estimated precaution time for holding children in the spoon position while sitting was also calculated.
Results:
Different radiation dose rate measurement scenarios showed different variation tendencies. Radiation dose rate measurement showed higher mean values of measured radiation dose tendency in the standing position than in the sitting positions. The measurement from the anterior direction showed a slightly lower tendency than that from the posterior direction. Assuming a dose limit of 1 mSv, the precaution time calculated for children being held in the spoon position for a certain duration every day was 51.5 (range, 12.5-152.2) minutes.
Conclusions:
Our study presented a supplemental radiation exposure measurement data set and directly compared different measurement scenarios. Several trends in radiation exposure variations were found in the measurement scenarios at different body postures and different measurement directions. Our study data set could be a useful source of concrete information regarding radiation safety and contribute to the review and revision of public guidance in the future.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET