A comparison of automatic and manual compensation methods for the calculation of tube currents during off-centered
Yasushi Furukawa1,2, Kosuke Matsubara3, Yoshinori Tsutsumi4
1Department of Radiological Technology, Nagoya University Hospital, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8560, Japan. y_furukawa1103@yahoo.co.jp.
Abstract:
Automatic exposure control (AEC) is used to optimize the X-ray tube output during computed tomography (CT) scans. However, calculation of the tube current by AEC can be affected when a patient is not aligned with the rotational center of the X-ray tube. An automatic couch height-positioning compensation mechanism provides a corrective function when the patient is off-center. In this study, we aimed to (a) evaluate the performance characteristics of the positioning compensation mechanism and (b) confirm whether our proposed compensation method can be properly applied to a noise-based AEC system even if the CT device is not equipped with a positioning compensation mechanism. An elliptical phantom was scanned at various table heights on systems without/with the positioning compensation mechanism. Expressions describing the offset from the gantry's isocenter and adjusted standard deviation settings were derived and used in our proposed compensation method. A phantom was scanned at various table heights with our proposed compensation method, and volume CT dose index (CTDIvol) and image noise levels were obtained. An anthropomorphic chest phantom was also scanned using the proposed compensation method to verify its accuracy. When the positioning compensation mechanism was used, it yielded a constant CTDIvol and image noise levels at various table heights tested. A comparison between our proposed method and the positioning compensation mechanism for both the elliptical and chest phantoms yielded similar CTDIvol. Therefore, both automatic and manual positioning compensation methods are useful for avoiding AEC miscalculations in off-centered patient positioning cases.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:50Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...