Single-pass metal artifact reduction using a dual-layer flat panel detector.

Linxi Shi1, N Robert Bennett1, Amy Shiroma2

  • 1Department of Radiology, Stanford University, Stanford, CA, USA.

Medical Physics
|August 10, 2021
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Deep-learning-based multiple organ segmentation for CT scout images: applications to automatic CT planning.

Journal of medical imaging (Bellingham, Wash.)·2026
Same author

Characterization of Thick Selenium Layers for Dual-Layer X-ray Imaging.

IEEE transactions on nuclear science·2026
Same author

A comparative analysis of two dual-layer flat panel detector designs and mimicking of a triple-layer flat panel detector in spectral CT.

Medical physics·2026
Same author

Implicitly Defined Material Decomposition Estimator and Learned Physics-Informed Neural Proxy for Photon Counting CT.

IEEE transactions on medical imaging·2026
Same author

Improving the efficiency of normalized metal artifact reduction via a unified forward projection.

Physics in medicine and biology·2026
Same author

OpenDosimeter: Open hardware personal X-ray dosimeter.

Communications engineering·2025
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

This study introduces a novel single-pass metal artifact reduction (MAR) method using dual-energy imaging. The technique effectively reduces artifacts from metal implants in cone-beam CT, outperforming existing methods and speeding up reconstruction.

Area of Science:

  • Medical Imaging
  • Cone-Beam CT
  • Image Reconstruction

Background:

  • Metal artifacts pose a significant challenge in cone-beam CT (CBCT) imaging, degrading image quality and diagnostic accuracy.
  • Traditional metal artifact reduction (MAR) methods often require two-pass reconstruction, which can be time-consuming and may fail with off-center or moving metal objects.
  • Single-pass methods exist but often struggle with accurate metal detection, leading to residual artifacts.

Purpose of the Study:

  • To develop and evaluate a novel single-pass MAR method utilizing dual-energy (DE) imaging with a dual-layer (DL) detector.
  • To improve the robustness and accuracy of metal artifact reduction, particularly in cases of field-of-view (FOV) truncation or when metal objects are outside the scan FOV.
  • To reduce the overall processing time compared to conventional two-pass MAR techniques.
Keywords:
cone-beam CTdual-layerflat panel detectormaterial decompositionmetal artifact

More Related Videos

Microfabricated Post-Array-Detectors mPADs: an Approach to Isolate Mechanical Forces
61:34

Microfabricated Post-Array-Detectors mPADs: an Approach to Isolate Mechanical Forces

Published on: October 1, 2007

12.7K
Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
12:08

Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System

Published on: July 18, 2015

10.9K

Related Experiment Videos

Last Updated: Oct 25, 2025

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

2.0K
Microfabricated Post-Array-Detectors mPADs: an Approach to Isolate Mechanical Forces
61:34

Microfabricated Post-Array-Detectors mPADs: an Approach to Isolate Mechanical Forces

Published on: October 1, 2007

12.7K
Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
12:08

Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System

Published on: July 18, 2015

10.9K

Main Methods:

  • Metal objects were directly detected in projections using DE imaging, generating material-specific images where metal is clearly delineated.
  • Metal detection was achieved through thresholding and entropy filtration to minimize false positives.
  • Scatter correction was applied to DE raw projections to enhance material decomposition accuracy.
  • Image reconstruction was performed using filtered backprojection after correcting identified metal regions via interpolation.
  • The method was evaluated using phantoms mimicking liver biopsy and a cadaver head with dental fillings and external metal tags.

Main Results:

  • The proposed DE-based MAR method demonstrated robustness to FOV truncation, outperforming standard two-pass reconstruction in such cases.
  • Metal segmentation accuracy was superior to Markov Random Field (MRF) and single-energy methods, which were prone to false-positive errors.
  • For a liver biopsy phantom, spatial nonuniformity was reduced from 0.127 to 0.077.
  • In a cadaver head scan, average standard deviation in soft tissue regions decreased from 209.1 HU to 46.8 HU.
  • Processing time was reduced by 31% compared to the two-pass method.

Conclusions:

  • A novel, single-pass MAR method using DE imaging has been successfully developed.
  • The method is robust to truncation artifacts and offers superior performance compared to single-energy imaging techniques.
  • This approach significantly reduces processing time, offering a more efficient solution for metal artifact reduction in CBCT.