In vitro models to evaluate ingestible devices: Present status and current trends
Connor O'Farrell1, Konstantinos Stamatopoulos2, Mark Simmons1
1School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK.
Orally ingestible medical devices require advanced models for gastrointestinal (GI) simulation. This review details in vitro tools for characterizing these devices, aiding selection based on function.
Area of Science:
- Gastroenterology and Biomedical Engineering
- Drug Delivery Systems
- Medical Device Development
Background:
- Orally ingestible medical devices present significant opportunities for diagnosing and treating gastrointestinal conditions.
- Developing these devices requires accurate models that simulate the complex gastrointestinal environment at macro and micro levels.
- Advancements in scientific technology have led to diverse in vitro, ex vivo, and in vivo models replicating the gastrointestinal tract.
Purpose of the Study:
- To review the current landscape of in vitro tools available for characterizing orally ingestible medical devices.
- To present the benefits and limitations of various in vitro models in the context of evaluating ingestible devices.
- To provide examples of model application in the evaluation of ingestible devices where available.
Main Methods:
- Systematic review of existing in vitro models for ingestible device characterization.
- Analysis of model benefits, limitations, and applicability to ingestible device evaluation.
- Compilation of case examples demonstrating the use of these models.
Main Results:
- A wide range of in vitro tools exists for characterizing ingestible devices.
- Each model possesses unique benefits and limitations impacting its suitability for specific device evaluations.
- Model selection should be guided by the ingestible device's functionality and mechanism of action.
Conclusions:
- The multitude of available in vitro models offers a comprehensive suite of tools for ingestible device evaluation.
- Choosing the appropriate model is crucial and depends on the specific device's intended function and operational mechanism.
- Effective characterization using tailored in vitro models is essential for the successful development of orally ingestible medical devices.
More Related Videos
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Release Testing: Overview, Development and Validation
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
In Vitro Drug Dissolution: Alternative Methods