Related Experiment Video
Updated: Oct 23, 2025

A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
Assessing the stability of one-stage PN/A process through experimental and modelling investigations
Jia Meng1, Tao Liu2, Jing Zhao2
1State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, 73 Huanghe Road, Harbin 150090, China; Advanced Water Management Centre, The University of Queensland, St Lucia, QLD 4072, Australia.
Abstract:
The mainstream partial nitritation/anammox (PN/A) process has been intensively studied but its stability remains a key challenge. It is shown here that biofilm thickness can exhibit a critical role in controlling the process stability of mainstream PN/A against dissolved oxygen (DO) variation. In a laboratory moving bed biofilm reactor (MBBR), PN/A performance was initially established in 200 days by controlling a low DO of 0.13 ± 0.07 mg O2/L in the bulk liquid, which deteriorated with an increase of DO (0.35 ± 0.13 mg O2/L) for over two months, and then rapidly recovered in a month with the initial low DO level re-applied. Biofilm thickness of PN/A carriers was measured during the experiment, which became significantly thinner (367 ± 146 μm) at mainstream conditions. The thin thickness primarily decreased the in-situ consumption rate of nitrite, rather than ammonium, when DO increased from 0.1 to 0.4 mg O2/L, due to that the thin thickness can only restrict anammox capacity. These results illustrated the role of biofilm thickness in regulating PN/A performance and microbial activities. Further investigation using an established model revealed the joint contribution of biofilm thickness and DO concentration to PN/A process, while particularly, the biofilm thickness can determine the optimal DO level for maximizing the nitrogen removal efficiency and system robustness against DO variation. These results highlight the need of considering biofilm thickness in PN/A process optimization and stability improvement in low-strength wastewater treatment.
More Related Videos
20:24Characterization of Complex Systems Using the Design of Experiments Approach: Transient Protein Expression in Tobacco as a Case Study
Published on: January 31, 2014
10:37Procedure to Evaluate the Efficiency of Flocculants for the Removal of Dispersed Particles from Plant Extracts
Published on: April 9, 2016
Related Concept Videos
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...