Average and longest expected treatment times for ultraviolet light disinfection of rooms
Franklin Dexter1, Bradlee Birchansky1, Richard H Epstein2
1Department of Anesthesia, University of Iowa, Iowa City, IA.
Background:
Planning Ultraviolet-C (UV-C) disinfection of operating rooms (ORs) is equivalent to scheduling brief OR cases. The study purpose was evaluation of methods for predicting surgical case duration applied to treatment times for ORs and hospital rooms.
Methods:
Data used were disinfection times with a 3-tower UV-C disinfection system in N=700 rooms each with ≥100 completed treatments.
Results:
The coefficient of variation of mean treatment duration among rooms was 19.6% (99% confidence interval [CI] 18.2%-21.0%); pooled mean 18.3 minutes among the 133,927 treatments. The 50th percentile of coefficients of variation among treatments of the same room was 27.3% (CI 26.3%-28.4%), comparable to variabilities in durations of surgical procedures. The ratios of the 90th percentile to mean differed among rooms. Log-normal distributions had poor fits for 33% of rooms. Combining results, we calculated 90% upper prediction limits for treatment times by room using a distribution-free method (e.g., third longest of preceding 29 durations). This approach was suitable because, once UV-C disinfection started, the median difference between the duration estimated by the system and actual time was 1 second.
Conclusions:
Times for disinfection should be listed as treatment of a specific room (e.g., "UV-C main OR16"), not generically (e.g., "UV-C"). For estimating disinfection time after single surgical cases, use distribution-free upper prediction limits, because of considerable proportional variabilities in duration.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Antimicrobial Effectiveness
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...