Related Experiment Video
Updated: Oct 21, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
T2-weighted Imaging of the Breast at 1.5T Using Simultaneous Multi-slice Acceleration
Julia Riffel1, Stephan Kannengiesser2, Stefan O Schoenberg3
1Clinic of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany; julia.riffel@medma.uni-heidelberg.de.
Aim:
To evaluate the image quality and time saving using simultaneous multi-slice (SMS)-accelerated T2-weighted turbo spin echo (TSE) sequences compared to standard T2 TSE sequences in breast magnetic resonance imaging (MRI).
Patients And Methods:
Thirty patients were examined with an SMS-accelerated T2 TSE sequence and a standard T2 TSE sequence as part of a breast MRI protocol at 1.5T. Image quality, signal homogeneity and tissue delineation were evaluated. For quantitative assessment, the signal-to-noise ratio (SNR) was measured from representative SNR maps.
Results:
There were no significant differences regarding tissue delineation and signal homogeneity. Image quality was rated equal at the chest wall and the breasts but decreased in the axilla on SMS-T2 TSE (p=0.01) with a simultaneous decrease of SNR (p=0.03). This did not significantly impact the overall image quality (p=0.2). The acquisition time for SMS-T2 TSE was 48% shorter compared to standard T2 TSE.
Conclusion:
SMS-acceleration for T2-weighted imaging of the breast at 1.5T substantially reduces acquisition time while maintaining comparable quantitative and qualitative image quality. This may pave the way for protocol abbreviation especially in a high-throughput clinical workspace.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System IV: CMRI