Related Experiment Video
Updated: Oct 20, 2025

Micromechanical Tension Testing of Additively Manufactured 17-4 PH Stainless Steel Specimens
Published on: April 7, 2021
Push-Out Method for Micro Measurements of Interfacial Strength in Aluminium Alloy Matrix Composites
Rafał Kozera1,2, Anna Boczkowska1,2, Zuzanna D Krawczyk1
1Faculty of Materials Science and Engineering, Warsaw University of Technology, ul. Woloska 141, 02-507 Warszawa, Poland.
Abstract:
The main goal of this work was the evaluation of the interfacial strength of the carbon fibres/aluminium matrix interface dependently on the utilised composite fabrication method, namely high pressure die casting and gas pressure infiltration. In addition, the influence of a Ni-P coating on the C-fibres was investigated. The proposed measurements of the interfacial strength were carried out by means of the "push-out" method. The interfacial strength of the samples fabricated using the high-pressure infiltration method average between 19.03 MPa and 45.34 MPa.