Brightfield, fluorescence, and phase-contrast whole slide imaging via dual-LED autofocusing
Chengfei Guo1,2,3, Zichao Bian2,3, Soliman Alhudaithy2,4,3
1Xi'an Key Laboratory of Computational Imaging, Xidian University, Shaanxi, 710071, China.
Abstract:
Whole slide imaging (WSI) systems convert the conventional biological samples into digital images. Existing commercial WSI systems usually require an expensive high-performance motorized stage to implement the precise mechanical control, and the cost is prohibitive for most individual pathologists. In this work, we report a low-cost WSI system using the off-the-shelf components, including a computer numerical control (CNC) router, a photographic lens, a programmable LED array, a fluorescence filter cube, and a surface-mount LED. To perform real-time single-frame autofocusing, we exploited two elements of a programmable LED array to illuminate the sample from two different incident angles. The captured image would contain two copies of the sample with a certain separation determined by the defocus distance of the sample. Then the defocus distance can be recovered by identifying the translational shift of the two copies. The reported WSI system can reach a resolution of ∼0.7 µm. The time to determine the optimal focusing position for each tile is only 0.02 s, which is about an 83% improvement compared to our previous work. We quantified the focusing performance on 1890 different tissue tiles. The mean focusing error is ∼0.34 µm, which is well below the ± 0.7 µm depth of field range of our WSI system. The reported WSI system can handle both the semitransparent and the transparent sample, enabling us to demonstrate the implementation of brightfield, fluorescence, and phase-contrast WSI. An automatic digital distortion correction strategy is also developed to avoid the stitching errors. The reported prototype has an affordable cost and can make it broadly available and utilizable for individual pathologists as well as can promote the development of digital pathology.
More Related Videos
06:52Optimized Workflow for Iterative Bleaching Extends Multiplexity Imaging of Highly Autofluorescent Clinical Samples
Published on: July 11, 2025
12:51Simultaneous Multicolor Imaging of Biological Structures with Fluorescence Photoactivation Localization Microscopy
Published on: December 9, 2013
Related Concept Videos
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Two-Dimensional Microscopy in Microbiology
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...