Related Experiment Video
Updated: Oct 20, 2025

Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
[Comparison two blood culture bottles for the recovery of Enterobacteriaceae]
A De Malet1, M García-Merino, S Velasco
1Ana De Malet, Department of Microbiology, University Hospital Marqués de Valdecilla-IDIVAL,C antabria, Spain. dmaletpf@hotmail.com.
Objective:
The objective of the present study was to compare the suitability of the B BACTEC™ Lytic/10 Anaerobic/F versus B BACTEC™ Plus Aerobic/F vials at the time of both Enterobacteriaceae recovery rate and detection time.
Methods:
Prospective observational study from September 2018 to January 2019 in which 150 bacteremia. The samples were incubated in the automated BD BACTEC ™ FX system (Becton Dickison).
Results:
A total of 180 Enterobacteriaceae were isolated: 93 B BACTEC™ Plus Aerobic/F and 87 from B BACTEC™ Lytic/10 Anaerobic/F belonging to 106 patients The urinary focus was the most frequent origin. The average detection time in both cases was not more than 15 hours.
Conclusions:
The combination of both bottles seems to be the best diagnostic strategy, thus reducing the detection time as well as increasing the recovery of Enterobacteriaceae. The combination of both vials could be implemented especially in selected situation of special urgency such as the sepsis code or critical patients.