Related Experiment Video
Updated: Oct 19, 2025

Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Voice changes after surgically assisted rapid maxillary expansion
Onur Erdem Erdur1, Berza Sen Yilmaz2
1Private practice, Istanbul, Turkey.
Introduction:
This study aimed to investigate voice changes in patients who had surgically assisted rapid maxillary expansion (SARME).
Methods:
Nineteen adult patients with maxillary transverse deficiency were asked to pronounce the sounds "[a], [ϵ], [ɯ], [i], [ɔ], [œ] [u], [y]" for 3 seconds. Voice records were taken before the expansion appliance was placed (T0) and 5.8 weeks after removal (T1, after 5.2 months of retention). The same records were taken for the control group (n = 19). The formant frequencies (F0, F1, F2, and F3), shimmer, jitter, and noise-to-harmonics ratio (NHR) parameters were considered with Praat (version 6.0.43).
Results:
In the SARME group, significant differences were observed in the F1 of [a] (P = 0.005), F2 of [ϵ] (P = 0.008), and [œ] sounds (P = 0.004). The postexpansion values were lower than those recorded before. In contrast, the F1 of [y] sound (P = 0.02), F2 of [u] sound (P = 0.01), the jitter parameter of [ɯ] and [i] sounds (P = 0.04; P = 0.002), and the NHR value of [ϵ] sound (P = 0.04) were significantly than the baseline values. In the comparison with the control group, significant differences were found in the F0 (P = 0.025) and F1 (P = 0.046) of the [u] sound, the F1 of the [a] sound (P = 0.03), and the F2 of the [ϵ] sound (P = 0.037). Significant differences were also found in the shimmer of [i] (P = 0.017) and [ɔ] (P = 0.002), the jitter of [ϵ] (P = 0.046) and [i] (P = 0.017), and the NHR of [i] (P = 0.012) and [ɔ] (P = 0.009).
Conclusion:
SARME led to significant differences in some of the acoustics parameters.
More Related Videos
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...

