Related Experiment Video
Updated: Oct 19, 2025

Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018
Possibility of new shielding device for upper gastrointestinal endoscopy
Daisuke Kikuchi1, Daiki Ariyoshi2, Yugo Suzuki1
1Department of Gastroenterology, Toranomon Hospital, Tokyo Japan.
Abstract:
Background and study aims Infection control is essential when performing endoscopic procedures, especially during the COVID-19 pandemic. Therefore, we have developed a new shielding device called STEP for infection control in upper gastrointestinal endoscopy. Patients and methods STEP consists of a mask worn by the patient and a drape that is connected to the mask and covers the endoscope. A suction tube attached to the mask prevents aerosols from spreading. The endoscopist operates the endoscope through the drape. Three endoscopists performed a total of 18 examinations using an upper endoscopy training model with and without STEP. Endoscopic images were evaluated by three other endoscopists, using a visual analog scale. We also simulated contact, droplet, and aerosol infection and evaluated the utility of STEP. Results All examinations were conducted without a problem. Mean procedure time was 126.3 ± 11.6 seconds with STEP and 122.3 ± 10.0 seconds without STEP. The mean visual analog score was 90.7 ± 10.1 with STEP and 90.4 ± 10.0 without STEP. In the contact model, adherence of simulated contaminants was 4.9 ± 1.4 % without STEP and 0 % with STEP. In the droplet model, the number of simulated contaminants attached to the paper was 338 273 ± 90 735 pixels without STEP and 0 with STEP. In the aerosol model, the total number of particles was 346 837 ± 9485 without STEP and was significantly reduced to 222 ± 174 with STEP. Conclusions No effect on examination time or endoscopic image quality was observed when using STEP in upper gastrointestinal endoscopy. Using STEP reduced the diffusion of simulated contaminants in all three infection models.
More Related Videos
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures III: Video Capsule Endoscopy
Drugs for Peptic Ulcer Disease: Sucralfate as Mucosal Protective Agents
In this scenario, mucosal protective agents like sucralfate play an essential role. Sucralfate, a complex of sulfated sucrose and aluminum hydroxide, demonstrates its usefulness in acidic conditions,...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.

