Sara Martínez Castro1, Francisco Javier Belda Nacher2, Carlos Delgado Navarro3
1Hospital Clínico Universitario, Valencia, Spain. saradacuris@hotmail.com aquereparteledicia@gmail.com.
Background:
The growing number of patients on home mechanical ventilation has driven considerable progress in the performance and functionality of ventilators, with features comparable with those used in the ICU. However, a publication gap exists in the evaluation and comparison of their performance and each ventilator choice depends on machine characteristics defined by manufacturers.
Methods:
We bench tested 8 home-care ventilators that are currently available: Monnal T50, EOVE EO-150, Puritan Bennet 560, Weinmann, PrismaVent 50, Trilogy Evo, Astral 150, and Vivo 60 by using an active lung model. These devices were tested under 18 experimental conditions that combined 3 variables: respiratory mechanics, ventilatory mode, and inspiratory muscle effort. The volume delivered, trigger response, pressurization capacity, and synchronization were analyzed.
Results:
Significant differences were observed in the performance among the devices. Decreased inspiratory muscle effort caused changes in the delivered volume, which worsened the response-to-trigger time, pressurization capacity, and synchronization. Increased pressure support favored the development of asynchronies. All the ventilators developed asynchronies under at least 1 set of conditions, but the EOVE and Trilogy Evo ventilators showed the fewest asynchronies during the experimental conditions studied.
Conclusions:
Great variability in terms of technical performance was observed among the 8 home-care ventilators analyzed. Asynchronies became a major issue when home mechanical ventilation was used under higher pressure-support values and lower muscle efforts. Our results may prove to be useful in helping choose the best suited machine based on a patient's clinical therapy needs.
More Related Videos
09:37Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment RMCA in Individuals with Chronic Spinal Cord Injury
Published on: July 19, 2013
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...