Related Experiment Video
Updated: Oct 18, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
A Temperature-Compensation Technique for Improving Resolver Accuracy
Wandee Petchmaneelumka1, Vanchai Riewruja1, Kanoknuch Songsuwankit1
1School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Ladkrabang, Bangkok 10520, Thailand.
Abstract:
Variation in the ambient temperature deteriorates the accuracy of a resolver. In this paper, a temperature-compensation technique is introduced to improve resolver accuracy. The ambient temperature causes deviations in the resolver signal; therefore, the disturbed signal is investigated through the change in current in the primary winding of the resolver. For the proposed technique, the primary winding of the resolver is driven by a class-AB output stage of an operational amplifier (opamp), where the primary winding current forms part of the supply current of the opamp. The opamp supply-current sensing technique is used to extract the primary winding current. The error of the resolver signal due to temperature variations is directly evaluated from the supply current of the opamp. Therefore, the proposed technique does not require a temperature-sensitive device. Using the proposed technique, the error of the resolver signal when the ambient temperature increases to 70 °C can be minimized from 1.463% without temperature compensation to 0.017% with temperature compensation. The performance of the proposed technique is discussed in detail and is confirmed by experimental implementation using commercial devices. The results show that the proposed circuit can compensate for wide variations in ambient temperature.
Related Concept Videos
Distance Corrections
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Adjusting a Traverse
Common Leveling Mistakes and Errors
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...

