Related Experiment Video
Updated: Oct 18, 2025

Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.
Published on: September 18, 2014
Gastric examination using a novel three-dimensional magnetically assisted capsule endoscope and a hand-held magnetic
Dong Jun Oh1, Ji Hyung Nam1, Junseok Park2
1Department of Internal Medicine, Dongguk University College of Medicine, Dongguk University Ilsan Hospital, Goyang, Republic of Korea.
Abstract:
Magnetically assisted capsule endoscopy (MACE) is a noninvasive procedure and can overcome passive capsule movement that limits gastric examination. MACE has been studied in many trials as an alternative to upper endoscopy. However, to increase diagnostic accuracy of various gastric lesions, MACE should be able to provide stereoscopic, clear images and to measure the size of a lesion. So, we conducted the animal experiment using a novel three-dimensional (3D) MACE and a new hand-held magnetic controller for gastric examination. The purpose of this study is to assess the performance and safety of 3D MACE and hand-held magnetic controller through the animal experiment. Subsequently, via the dedicated viewer, we evaluate whether 3D reconstruction images and clear images can be obtained and accurate lesion size can be measured. During real-time gastric examination, the maneuverability and visualization of 3D MACE were adequate. A polypoid mass lesion was incidentally observed at the lesser curvature side of the prepyloric antrum. The mass lesion was estimated to be 10.9 x 11.5 mm in the dedicated viewer, nearly the same size and shape as confirmed by upper endoscopy and postmortem examination. Also, 3D and clear images of the lesion were successfully reconstructed. This animal experiment demonstrates the accuracy and safety of 3D MACE. Further clinical studies are warranted to confirm the feasibility of 3D MACE for human gastric examination.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: