Positron Emission Tomography01:29

Positron Emission Tomography

6.1K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
6.1K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

264
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
264
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

883
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
883

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-precision measurement of the <i>W</i> boson mass with the CDF II detector.

Science (New York, N.Y.)·2022
Same author

Air-transfer production method for large-area picosecond photodetectors.

The Review of scientific instruments·2020
Same author

Search for the Exotic Meson X(5568) with the Collider Detector at Fermilab.

Physical review letters·2018
Same author

Combined Forward-Backward Asymmetry Measurements in Top-Antitop Quark Production at the Tevatron.

Physical review letters·2018
Same author

Single-Molecule Characterization of DNA-Protein Interactions Using Nanopore Biosensors.

Methods in enzymology·2017
Same author

Pump-probe spectrometer for measuring x-ray induced strain.

Optics letters·2016
Same journal

Design and realization of a sputter deposition system for the <i>in situ</i> and <i>in operando</i> use in polarized neutron reflectometry experiments: Novel capabilities.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2026
Same journal

Monte Carlo Modeling of An Experimental Benchtop L-shell X-ray Fluorescence Imaging/CT System Adopting Two Silicone Drift Detectors.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2025
Same journal

Autonomous screening of complex phase spaces using Bayesian optimization for SAXS measurements.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2025
Same journal

Integration of an electron beam ion trap source into an electrostatic accelerator for pre-clinical cancer research.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2025
Same journal

Characterization of external optical crosstalk reduction for SiPM-based scintillation detectors with an optical bandpass filter.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2025
Same journal

Cold neutron radiation dose effects on a <sup>6</sup>LiF:ZnS(Ag) neutron detector with wavelength shifting fibers and SiPM photodetector.

Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment·2024
See all related articles

Related Experiment Video

Updated: Oct 15, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.7K

Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media.

J F Shida1, E Spieglan1, B W Adams2

  • 1Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637.

Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
|October 25, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces novel Positron Emission Tomography (PET) scanners using low atomic number materials. These scanners enable precise gamma-ray interaction localization, potentially reducing patient radiation dose.

Keywords:
Compton ScatteringIonization ActivationLAPPDLow DoseLow-Z MediumMCP-PMTPersistent ImagePositron-Emission TomographyTOF resolutionTime-of-Flightphotoswitchable Fluorophores

More Related Videos

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

439
Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
10:47

Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging

Published on: February 3, 2015

8.9K

Related Experiment Videos

Last Updated: Oct 15, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.7K
Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

439
Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
10:47

Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging

Published on: February 3, 2015

8.9K

Area of Science:

  • Medical Imaging Physics
  • Quantum Materials Science
  • Nuclear Instrumentation

Background:

  • Current Positron Emission Tomography (PET) scanners face limitations in spatial resolution and radiation dose.
  • The Compton scattering process in PET detectors is fundamental but challenging to fully exploit for precise event localization.
  • Developing new detector media and methodologies is crucial for advancing PET imaging capabilities.

Purpose of the Study:

  • To propose and simulate a novel PET scanner design utilizing low atomic number media.
  • To leverage the physics of Compton scattering for enhanced Line-of-Response (LOR) measurement.
  • To investigate a quantum-mechanical state-change mechanism for improved PET imaging and dose reduction.

Main Methods:

  • Simulations of Compton scatter interactions in low atomic number media.
  • Utilizing kinematical constraints of 2-body Compton scattering for statistical time-ordering of events.
  • Employing a photoswitchable organic dye ('Switchillator') activated by recoil electrons.
  • Integrating time-of-flight microchannel plate photomultiplier tubes (MCP-PMTs) for precise timing and spatial resolution.

Main Results:

  • Demonstrated high-resolution LOR measurement determined by physics, not detector segmentation.
  • Simulated a 'Switchillator' dye changing to a fluorescent state upon electron ionization.
  • Achieved energy resolution by counting activated molecules and sub-millimeter spatial resolution.
  • Simulations indicate a significant potential reduction in patient radiation dose.

Conclusions:

  • The proposed PET scanner design offers a promising approach to overcome current resolution and dose limitations.
  • Exploiting quantum-mechanical state changes in detector media represents a novel pathway for PET innovation.
  • This technology has the potential to significantly improve the accuracy and safety of PET imaging.