Related Experiment Video
Updated: Oct 14, 2025

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Correntropy-induced metric with Laplacian kernel for robust fluorescence molecular tomography
Yating Yuan1,2, Hongbo Guo1,2, Huangjian Yi1,2
1The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China.
Abstract:
Fluorescence molecular tomography (FMT), which is used to visualize the three-dimensional distribution of fluorescence probe in small animals via the reconstruction method, has become a promising imaging technique in preclinical research. However, the classical reconstruction criterion is formulated based on the squared l 2-norm distance metric, leaving it prone to being influenced by the presence of outliers. In this study, we propose a robust distance based on the correntropy-induced metric with a Laplacian kernel (CIML). The proposed metric satisfies the conditions of distance metric function and contains first and higher order moments of samples. Moreover, we demonstrate important properties of the proposed metric such as nonnegativity, nonconvexity, and boundedness, and analyze its robustness from the perspective of M-estimation. The proposed metric includes and extends the traditional metrics such as l 0-norm and l 1-norm metrics by setting an appropriate parameter. We show that, in reconstruction, the metric is a sparsity-promoting penalty. To reduce the negative effects of noise and outliers, a novel robust reconstruction framework is presented with the proposed correntropy-based metric. The proposed CIML model retains the advantages of the traditional model and promotes robustness. However, the nonconvexity of the proposed metric renders the CIML model difficult to optimize. Furthermore, an effective iterative algorithm for the CIML model is designed, and we present a theoretical analysis of its ability to converge. Numerical simulation and in vivo mouse experiments were conducted to evaluate the CIML method's performance. The experimental results show that the proposed method achieved more accurate fluorescent target reconstruction than the state-of-the-art methods in most cases, which illustrates the feasibility and robustness of the CIML method.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Super-resolution Fluorescence Microscopy
Confocal Fluorescence Microscopy
Two-Dimensional Microscopy in Microbiology
Total Internal Reflection Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

