Related Experiment Video
Updated: Oct 12, 2025

Fabrication of the Composite Regenerative Peripheral Nerve Interface C-RPNI in the Adult Rat
Published on: February 25, 2020
Reconstruction of the Rat Sciatic Nerve by Using Biodegradable and Non-Biodegradable Conduits
A G Velichanskaya1, D A Abrosimov2, M L Bugrova3
1Associate Professor, Department of Histology, Cytology, and Embryology; Privolzhsky Research Medical University, 10/1 Minin and Pozharsky Square, Nizhny Novgorod, 603005, Russia.
Abstract:
The aim of the study was to compare two types of conduits made of either non-resorbable Reperen or resorbable Tissucol for their effects on the regeneration of the rat sciatic nerve under conditions of stump diastasis.
Materials And Methods:
The experiments were carried out using outbred white male rats of the reproductive age (n=14). The animals were divided into three groups: group 1, intact (n=5), used for studying the morphology of the sciatic nerve; group 2 (n=4) - nerve plastic surgery was performed using a conduit made of non-resorbable Reperen; group 3 (n=5) - surgery was performed using a conduit made of resorbable Tissucol. The animals were anesthetized with isoflurane. After a complete transection of the sciatic nerve in the middle third of the thigh, its stumps were inserted into a conduit of an internal diameter of 2 mm and a length of 10 mm, filled with saline. Diastasis of 5 mm in length was created by spreading the nerve ends and securing the epineurium to the tube edges with 8/0 polypropylene sutures. A total count of myelinated nerve fibers was performed in the area of repair (tubulation) and the distal part of the nerve; the formation of connective tissue sheaths was assessed 14 weeks after the operation.
Results:
According to the morphological assessment, both types of conduits (resorbable and non-resorbable) caused the similar number of fibers to restore in the distal part of the repaired nerve; clinical characteristics of the animals in both groups were close to each other and to the norm.
Conclusion:
The results allow us to consider the conduit made of non-resorbable Reperen as a device promising for neuroplasty along with the resorbable conduit made of Tissucol.
More Related Videos
08:05Transplantation of Schwann Cells Inside PVDF-TrFE Conduits to Bridge Transected Rat Spinal Cord Stumps to Promote Axon Regeneration Across the Gap
Published on: November 3, 2017
07:13Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
Published on: October 20, 2021