Related Experiment Video
Updated: Oct 12, 2025

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Adsorptive stripping voltammetric determination of chloramphenicol residues in milk samples using reduced graphene
Lucas Vinícius de Faria1, Thalles Pedrosa Lisboa1, Guilherme Figueira Alves1
1NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil. viniciuslucas82@yahoo.com.br.
Abstract:
In this paper, the electrochemical response of chloramphenicol (CHL) was investigated on a bare glassy carbon electrode (GCE) and after modification with reduced graphene oxide (GCE/rGO). Preliminary studies by cyclic voltammetry demonstrated an adsorption-controlled mass transport regime of CHL species and a pH-dependent behavior on both electrode surfaces. An adsorptive stripping differential pulse voltammetry (AdSDPV) method was proposed and under optimized instrumental conditions, a comparison of the analytical characteristics of both sensors was performed. The GCE/rGO sensor showed an increase in sensitivity (10-fold), and an anticipation of the reduction potential (200 mV), compared to the bare electrode, due to the adsorptive character (pre-concentration of the CHL species) and the electrocatalytic effect of the nanomaterial. The method was applied to skimmed and whole milk samples, which were simply diluted (50-fold) in supporting electrolyte. The results by AdSDPV using GCE/rGO showed adequate detectability (0.22 μmol L-1), good precision with a 6% relative standard deviation (RSD) and satisfactory recovery ranging from 93 to 108%. The obtained results were statistically similar (95% confidence level) with those performed through ultra-fast liquid chromatography (UFLC). Furthermore, the sensor showed an improvement in the analytical performance for CHL detection, when compared to other sensors reported in the literature. Therefore, the developed method is reliable and promising for implementation in monitoring CHL residues in milk samples.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
07:51Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...