Comparison of False-Positive Versus True-Positive Findings on Contrast-Enhanced Digital Mammography
Tali Amir1, Molly P Hogan1, Stefanie Jacobs1
1Department of Radiology, Memorial Sloan Kettering Cancer Center, 300 E 66th St, Rm 711, New York, NY 10065.
Abstract:
BACKGROUND. Contrast-enhanced digital mammography (CEDM) has been shown to outperform standard mammography while performing comparably to contrast-enhanced MRI. OBJECTIVE. The purpose of our study was to compare imaging characteristics of false-positive and true-positive findings on CEDM. METHODS. This retrospective study included women who underwent baseline screening CEDM between January 2013 and December 2018 assessed as BI-RADS category 0, 3, 4, or 5 and who underwent biopsy with histopathologic diagnosis or had a 2-year imaging follow-up. Lesion characteristics were extracted from CEDM reports. A true-positive finding was defined as a lesion in which biopsy yielded malignancy. A false-positive finding was defined as a lesion in which biopsy yielded benign or benign high-risk pathology or in which 2-year imaging follow-up was negative. RESULTS. Of 157 patients (median age, 52 years), 24 had a total of 26 true-positive lesions, and 133 had a total of 147 false-positive lesions. Of the 26 true-positive lesions, one (4%) exhibited only a mammographic finding on low-iodine images, 13 (50%) exhibited only a contrast finding on iodine images, and 12 (46%) exhibited both a mammographic finding on low-energy images and a contrast finding on iodine images. A true-positive result was more likely (p = .02) for lesions present on both low-energy images and iodine images (31%) than on low-energy images only (4%) or iodine images only (12%). Among lesions present on both low-energy and iodine images, a true-positive result was more likely (p < .001) when the type of mammographic finding was an asymmetry (46%) or calcification (80%) than a mass (11%) or distortion (0%). A true-positive result was more likely (p = .01) among those with, versus those without, an ultrasound correlate (36% vs 9%) and also was more likely (p = .02) among those with, versus those without, an MRI correlate (18% vs 2%). Of 25 false-positive calcifications, 24 had no associated mammographic enhancement; of five true-positive calcifications, four had mammographic enhancement. CONCLUSION. A low-energy mammographic finding with associated enhancement or a finding with a sonographic or MRI correlate predicts a true-positive result. Calcifications with associated enhancement had a high malignancy rate. Nonetheless, half of true-positive lesions enhanced on iodine images without a mammographic finding on low-energy images. CLINICAL IMPACT. These observations inform radiologists' management of abnormalities detected on screening CEDM.
More Related Videos
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Magnetic Resonance Imaging