Related Experiment Video
Updated: Oct 12, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
High-Bandwidth Hysteresis Compensation of Piezoelectric Actuators via Multilayer Feedforward Neural Network Based
Yanding Qin1,2, Yunpeng Zhang1,2, Heng Duan1
1Tianjin Key Laboratory of Intelligent Robotics, College of Artificial Intelligence, Nankai University, Tianjin 300350, China.
Abstract:
This paper proposes a feedforward and feedback combined hysteresis compensation method for a piezoelectric actuator (PEA) based on the multi-layer feedforward neural network (MFNN) inverse model. Under the scheme of direct inverse modeling, the MFNN is utilized as the feedforward hysteresis compensator, which can be directly identified from the measurements. The high modeling accuracy and high robustness of the MFNN help to increase the bandwidth of the closed-loop system. Experiments are conducted on a commercial PEA so as to verify the effectiveness of the proposed method. The superimposition of two sinusoidal signals is found to be efficient for the training of the MFNN. Closed-loop trajectory tracking experiments demonstrate that the bandwidth can be increased up to 1000 Hz and the maximum deviation can be maintained closed to the noise level. Meanwhile, there are only two parameters to be tuned in the proposed method, which guarantees ease of use for the inexperienced users. The proposed method successfully realizes high-precision hysteresis compensation performance across a wider frequency range.
More Related Videos
10:51An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
PI Controller: Design
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Phase-lead and Phase-lag Controllers
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...