Related Experiment Video
Updated: Oct 10, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Design and Development of a Wristband for Continuous Vital Signs Monitoring of COVID-19 Patients
Abstract:
The novel coronavirus disease (COVID-19), as a pandemic, has intensely impacted the global healthcare systems. Remote health monitoring of positive COVID-19 patients isolating at home has been identified as a practical approach to minimize the mortality rate. This work proposes a cost-effective and ease-to-use wristband with the capability of continuous real-time monitoring of heart rate (HR), respiration rate (RR), and blood oxygen saturation (SpO2), temperature and accelerometry. The proposed wristband comprises three different sensing elements, namely, PPG sensor, temperature sensor, and accelerometer. The sensors' output signals are transmitted via Bluetooth. Process of the PPG signals measured from the wrist anatomical position provides essential information regarding HR, RR, and SpO2. The deployed temperature sensor and accelerometer, measure the wearers' body temperature and physical activities. Experimental results obtained from a group of subjects demonstrate that the wristband can monitor HR, RR, SpO2, and body temperature with the Mean Absolute Errors (MAEs) of 2.75 bpm, 1.25 breaths/min, 0.64%, and 0.22 Co, respectively. Such a small variation confirms that the wristband can be potentially deployed in the public health network to determine and track patients infected by COVID-19.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.