On-line risk prediction models for acute type A aortic dissection surgery: validation of the German Registry of Acute
Duško G Nežić1, Igor S Živković1, Miroslav D Miličić1
1Department of Cardiac Surgery, "Dedinje" Cardiovascular Institute, Belgrade, Serbia.
Objectives:
The German Registry of Acute Aortic Dissection Type A (GERAADA) on-line score calculator to predict 30-day mortality in patients undergoing surgery for acute type A aortic dissection (ATAAD) was recently launched. Using the European System for Cardiac Operative Risk Evaluation II (EuroSCORE II), it is also possible to predict operative mortality for the same type of surgery. The goal of our study was to validate the prediction accuracy of these 2 on-line risk prediction models.
Methods:
Prospectively collected data for EuroSCORE II risk factors as well as all data for GERAADA scoring were extracted from an institutional database for 147 patients who underwent surgery for ATAAD between April 2018 and April 2021. The discriminative power was assessed using area under the receiver operating characteristic curve. The calibration of the models was tested by the Hosmer-Lemeshow statistics and by using the observed-to-expected (O/E) mortality ratio with the 95% confidence interval.
Results:
The observed operative mortality was 14.3%. The mean predicted mortality rates for the GERAADA score and the EuroSCORE II were 15.6% and 10.6%, respectively. The EuroSCORE II discriminative power (area under the curve = 0.799) significantly outperformed the discriminatory power of the GERAADA score (area under the curve = 0.550). The Hosmer-Lemeshow statistics confirmed good calibration for both models (P-values of 0.49 and 0.29 for the GERAADA score and the EuroSCORE II, respectively). The O/E mortality ratio certified good calibration for both scores [GERAADA score (O/E ratio of 0.93, 95% confidence interval: 0.53-1.33); EuroSCORE II (O/E ratio of 1.35, 95% confidence interval: 0.77-1.93)].
Conclusions:
The EuroSCORE II has better discriminative power for predicting operative mortality in ATAAD surgery than the GERAADA score. Both scores confirmed good calibration ability.
More Related Videos
05:31Murine Model of Thoracic Aortic Dissection Induced by Oral β-Aminopropionitrile and Subcutaneous Angiotensin II Infusion
Published on: May 16, 2025
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm IV: Nursing Management
Aortic Regurgitation I: Introduction
Aortic Regurgitation IV: Nursing Management