Related Experiment Video
Updated: Oct 9, 2025

Guided Endodontics: Three-Dimensional Planning and Template-Aided Preparation of Endodontic Access Cavities
Published on: May 24, 2022
Micro-CT evaluation of root canal preparation with rotary instrumentation on prototyped primary incisors
Rafael Dos Reis Moraes1, Renata Perez2, Aline Saddock Sá da Silva3
1Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Department of Pediatric Dentistry and Orthodontics, Rio de Janeiro, RJ, Brazil.
Abstract:
This study aimed to evaluate the endodontic instrumentation outcomes with asymmetrical files compared to reciprocating and hand files (HFs) in 3D-printed prototypes of upper primary incisors using micro-computed tomography (micro-CT). For this purpose, 50 prototypes were randomly divided (n = 10) according to the instrumentation technique as follows: HFs, a reciprocating file (WaveOne® Gold [WOG]), and three asymmetrical movement files: XP-Endo® Shaper (XPS), XP-Endo® Finisher (XPF), and XP Clean (XPC). The specimens were scanned and, after registration of the baseline and instrumented volumes, changes in the root canal volume (RCV), debris accumulation, removed root material volume (RRMV), non-instrumented areas, and the presence of cracks/perforations were quantified. Data were analyzed by analysis of variance and Student's t-test, while the effect size was calculated for statistically significant outcomes. All groups showed an increase in RCV after instrumentation (p < 0.05), but this was higher with HFs (p < 0.05). Accumulated debris was higher for WOG and XPS (p < 0.05), but WOG exhibited more in the medium and apical third areas. HFs showed the highest RRMV (p < 0.05), especially at the apical third. The non-instrumented areas were lower for HFs and XPC than for the other systems (p < 0.05). Cracks were present in a few WOG (n = 2) and HF specimens (n = 3) and in this group, one of the cracked specimens and two others showed perforations. The asymmetric systems resulted in conservative dentin removal and fewer cracks/perforations as compared to HFs and a reciprocation file in prototyped primary upper incisors. XPC showed the best compromise between RRMV and non-instrumented areas with a low accumulation of debris.
More Related Videos
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
07:03Dynamic Navigation in Endodontics: Guided Access Cavity Preparation by Means of a Miniaturized Navigation System
Published on: May 5, 2022