Automatic data extraction from 24 hour blood pressure measurement reports of a large multicenter clinical trial
Janis M Nolde1, Ajmal Mian2, Luca Schlaich1
1Dobney Hypertension Centre, Medical School - Royal Perth Hospital Unit, The University of Western Australia, Perth, Australia.
Background And Objectives:
Ambulatory blood pressure monitoring (ABPM) is usually reported in descriptive values such as circadian averages and standard deviations. Making use of the original, individual blood pressure measurements may be advantageous, particularly for research purposes, as this increases the flexibility of the analytical process, enables alternative statistical analyses and provide novel insights. Here we describe the development of a new multistep, hierarchical data extraction algorithm to collect raw data from .pdf reports and text files as part of a large multi-center clinical study.
Methods:
Original reports were saved in a nested file system, from which they were automatically extracted, read and saved into databases with custom made programs written in Python 3. Data were further processed, cleaned and relevant descriptive statistics such as averages and standard deviations calculated according to a variety of definitions of day- and night-time. Additionally, data control mechanisms for manual review of the data and programmatic auto-detection of extraction errors was implemented as part of the project.
Results:
The developed algorithm extracted 97% of the data automatically, the missing data consisted mostly of reports that were saved incorrectly or not formatted in the specified way. Manual checks comparing samples of the extracted data to original reports indicated a high level of accuracy of the extracted data, no errors introduced due to flaws in the extraction software were detected in the extracted dataset.
Conclusions:
The developed multistep, hierarchical data extraction algorithm facilitated collection from different file formats and paired with database cleaning and data processing steps led to an effective and accurate assembly of raw ABPM data for further and adjustable analyses. Manual work was minimized while data quality was ensured with standardized, reproducible procedures.
More Related Videos
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...